How to troubleshoot common faults in ABB dual speed motors
Date:2021-05-27 16:31:55
ABB dual speed motor operates normally at low speed, but cannot operate at high speed: ABB dual speed motor operates normally, indicating that the motor has no faults. The problem occurs in the high-speed running main circuit or control circuit. Check whether the start button SB2, contactor KM2 and KM3 coils and contacts are normal, and whether the normally closed interlock contacts of thermal relay FR2 and contactor KM1 are normal. If any problems are found, solve them immediately.
ABB dual speed motor cannot operate at both high and low speeds. Fault: First check if there is three-phase power input in the main circuit. Check if the circuit breaker and fuse are functioning properly. Determine if the motor is functioning properly. If there is a malfunction in the motor, it needs to be repaired. If the motor is not faulty and the circuit breaker and fuse are not faulty, it is necessary to check whether the contactor, thermal relay, and start button are normal, and whether the problem is in the main circuit or the control circuit. If a fault is found, it should be eliminated immediately. Use a multimeter to check if there is a short circuit or open circuit in the winding of the motor, and then check if the motor insulation is qualified.